Using inductive loads for Zimi switches
When wiring a Powermesh Multi Purpose switch ( PMMPSxxx) to an inductive load such as an exhaust fan, contactor, etc., the use of an RC Suppressor module is highly recommended as a safeguard. The RC Suppressor will normalise current spikes and maintain a more stable voltage level that can be caused by these inductive loads which could potentially damage the switch . Please note this is NOT DIY and installation must be carried out by a LICENSED ELECTRICIAN to local wiring regulations. FFew readersDo the Powermesh Light Dimmer and Switches require a neutral at the wall?
The Powermesh Light Dimmer and Multi Purpose Switches can be installed with or without a neutral wire at the wall (2 or 3 wire). For the best performance, always connect the neutral if available.Few readersUsing a contactor with a Powermesh switch
When wiring a Powermesh Multi Purpose switch ( PMMPSxxx) to a contactor, the use of an RC Suppressor module is highly recommended as a safeguard. The RC Suppressor will normalise current spikes and maintain a more stable voltage level that can be caused by these inductive loads which could potentially damage the switch. Please note this product is not DIY! Installation must only be installed by a LICENSED ELECTRICIAN to local wiring regulations. Failure to follow these instructions can resuFew readers